ORA-01450 During Online Index Rebuild

We hit an ORA-01450 error today trying to do online rebuild for an index in an unusable state. This was a non-unique index on a fairly large column — VARCHAR2(800 CHAR).

SQL> alter index i1 rebuild online;
alter index i1 rebuild online
*
ERROR at line 1:
ORA-00604: error occurred at recursive SQL level 1
ORA-01450: maximum key length (3215) exceeded

It rang a bell. I remembered that I encountered this issue a while ago, but I couldn’t recall the details. I know that it has nothing to do with the actual data size — it’s an error that can occur during index creation. A single index block must be able to fit at least two index entries, so the maximum index key size defined by the block size and overhead.

The key length is calculated as:

key length = sum of all column lengths
           + number of columns
           + 2 (key length)
           + 6 (restricted ROWID)
           + 1 (ROWID field length)

If I didn’t miss anything, the key length for my index should be 800 + 1 + 2 + 6 + 1 = 810. Hold on . . . we have character length semantic here — let’s check the database character set: